Part III of Article Conductors for General Wiring, covers the general installation requirements for conductors rated up to and including volts. Section Using the values shown in Table Also, Section Again, multiply the conductor ampacities as shown in the ampacity tables by the percentage values given in Table Incorrect answer.
Please choose another answer. Part VI of Article explains the wiring methods and installation requirements for equipment grounding and equipment grounding conductors. Article provides the general requirements for branch circuits. There are no exceptions to this rule, the receptacles must be provided with GFCI protection for the user of appliances or other equipment regardless of where the receptacle is located in the garage.
The uses and ampacity ratings of conductors for general wiring are found in Article Study Online Instantly. Article covers the rating and installation of receptacles. Note, the service-entrance conductors for dwellings, under this condition, is reduced in size in relation service-entrance conductors for commercial and industrial occupancies due to the dwelling unit's diversified load. Article governs the installation and use of all outlet and device boxes.
Table Therefore, the box is permitted to have only four 4 size 12 AWG conductors. Part III of Article provides the general requirements for the required volt, single-phase and ampere receptacle outlets in a dwelling unit. Additional required receptacle outlets are permitted to be located as determined by the installer, home owner, or builder. This rule eliminates the need for extension cords. This rule is in place to restrict voltage-drop and prevent nuisance tripping of the overcurrent protection device.
The rules for service equipment and service conductors and their installation requirements are found in Article This mandate was established because of the need for first responders and utility personnel to have a way to safely remove power from the house in an emergency. Part VI of Article covers the wiring methods and installation requirements for equipment grounding and equipment grounding conductors. However, Article covers motors, motor conductors, motor protection, motor controllers, motor control circuits, and motor control centers.
Overloads are not a fault condition, overloads happen when there is excessive current in the circuit. An overload is where the current is more than the equipment ampere rating and the overload may result in overheating and damaging equipment. Overload protection does not protect against short-circuits or ground-fault currents. Part II of Article addresses the general requirements for system grounding and bonding of alternating-current systems to be grounded.
The size of the main bonding jumper is determined in accordance with Table The provisions of Article apply to the installation and wiring methods of storable or permanently installed swimming pools, hot tubs and spas, and to their metallic auxiliary equipment, such as pumps and similar equipment.
Article applies to air-conditioning and refrigeration equipment and to branch circuits and controllers for the equipment. The rules regarding the use and installation of rigid metal conduit RMC are found in Article As per Section Article contains installation and other requirements for generators.
The path to becoming a licensed electrician is not a short one, however, which makes choosing the right school very important. Get connected with accredited electrical schools in your area. Input your zip to search for a school near you and start an exciting career in electrical today.
Here you can see how you did on each question, so you know exactly what you got right and what you still need to know before you apply for trucking jobs. Want to start this test from the beginning? Not pleased with your results or want to beat your current score?